Laboratory
Tests
No-Burn¨ is committed to
rigorous product testing and continuous product improvement. No-Burn¨ products have been tested
according to a number of applicable national standards over a variety of
substrates.
The
Testing Standards met include those published by the following organizations:
All
tests have been conducted by nationally accredited independent tested
laboratories such as:
TEST
RESULTS
NO-BURN¨
PLUS*
1. Class A rating.
Tested per ASTM E-84-05 (Intertek
Report No. 3083068)
2. Class A rating.
Tested per ASTM E-84-05 30 minute
test (Intertek Report No. 3083068)
3. Class A rating. Tested per ASTM E-84-05 (7 overcoats of
paint) (Intertek Report No. 3104972SAT-001)
NO-BURN¨
PLUS Mih* is:
1. UL Classified
under UL 723 (R20493)
2. Achieved zero
mold growth. Tested per ASTM
D5590-94 (PBR 030819-8-A)
*for details of specific
tests conducted on various products, refer to the individual test reports.
No Burn Products Summary Tabulation
|
Flame Spread |
Smoke Developed |
Substrate |
Class |
Overcoat |
Test Standard |
Test Report |
|
NB Plus |
||||||
|
5 |
25 |
Douglas Fir |
A |
NA |
ASTM E-84-05 (30 min) |
Intertek # 3083068 Rev 1
10-4-2005 |
|
15 |
20 |
Gypsum Board |
A |
Seven Overcoats Latex Paint |
ASTM E-84-05 |
Intertek #
3104972SAT-001 9-18-2006 |
|
NB Plus Mih |
||||||
|
5 |
50-110 |
Douglas Fir |
A |
NA |
UL 723 |
UL BMQX.R20493 4-17-2006 |
|
NB Plus (Room Corner Test) |
||||
|
Pass/Fail |
Substrate |
Duration of Test |
Test Standard |
Test Report |
|
Passed |
Wood Studs & OSB |
30 minutes |
NFPA 286 |
WFCI Report No. 07020B |
|
Passed |
OSB |
60 minutes |
NFPA 286 |
WFCI Report No. 07020C |
|
Passed |
Plywood |
30 minutes |
NFPA 286 |
WFCI Report No. 07020D |